Certifications
Certified to serve your needs
ICC, FM and UL certifications underscore our commitment to quality and dependability
New Millennium products are engineered and manufactured to exacting quality standards—both internally and externally. We are a Steel Joist Institute member company, fully certified to manufacture K-, LH- and DLH-Series steel joists and joist girders. New Millennium is also a Steel Deck Institute member company, fully certified to manufacture roof deck, form deck and composite floor deck.
ESR-4655
This report covers New Millennium steel roof deck type NW32™.
ESR-2657*
This report covers New Millennium steel roof panels: D4.5, D6.0 and D7.5 Deep-Dek® D4.5A, D6.0A and D7.5A Deep-Dek® Acoustical; D4.5C, D6.0C and D7.5C Deep-Dek® Cellular; D4.5CA, D6.0CA and D7.5CA Deep-Dek® Cellular Acoustical; Versa-Dek® Roof Deck Panels; and Versa-Dek® Acoustical Roof Deck Panels.
ESR-2635*
This report covers Versa-Dek® 2.0 S Composite, Versa-Dek® 2.0 LS Composite, Versa-Dek® 2.0 S ES Composite, Versa-Dek® 2.0 LS ES Composite, Versa-Dek® 3.5 LS Composite and Versa-Dek® 3.5 LS Composite Acoustical Deck Panels.
ESR-2839*
This report covers New Millennium composite floor deck panels: Deep-Dek® Composite 4.5, 6.0 and 7.5; Deep-Dek® Composite 4.5, 6.0 and 7.5 Cellular; and Deep-Dek® Composite 4.5, 6.0 and 7.5 Cellular Acoustical Floor Deck Panels.
ESR-3477
This report covers New Millennium Versa-Wedge® Steel Deck Hangers.
ESR-1169
This report covers New Millennium steel roof and floor deck panels made at the Memphis, TN facility, including B-Dek, N-Dek, NW32®, Composite Floor-Dek, and Form Deck (cellular versions included where applicable).
* These reports have supplemental Los Angeles Building Code approval
ESR-3477
This report covers New Millennium Versa-Wedge® Steel Deck Hangers.
ESR-1169
This report covers New Millennium steel roof and floor deck panels made at the Memphis, TN facility, including B-Dek, N-Dek, NW32®, Composite Floor-Dek, and Form Deck (cellular versions included where applicable).
* These reports have supplemental Los Angeles Building Code approval
FACTORY MUTUAL APPROVED STEEL DECKS
Versa-Dek® 2.0 LS ES
New Millennium steel roof deck type 2.0VLSES (dovetail) is approved for use as a component of Factory Mutual compliant roof systems.
Versa-Dek® 2.0 LS ES Acoustical
New Millennium steel roof deck type 2.0VLSESA (dovetail acoustical) is approved for use as a component of Factory Mutual compliant roof systems.
Versa-Dek® 3.5 LS
New Millennium steel roof deck type 3.5VLS (dovetail) is approved for use as a component of Factory Mutual compliant roof systems.
Versa-Dek® 3.5 LS Acoustical
New Millennium steel roof deck type 3.5VLSA (dovetail acoustical) is approved for use as a component of Factory Mutual compliant roof systems.
BI-Deck
New Millennium steel roof deck type BI (interlocking) is approved for use as a component of Factory Mutual compliant roof systems.
NW32 Deck™
New Millennium steel roof deck types NW32, NW32I, NW32A, and NW32IA (deep rib – DR) are approved for use as a component of Factory Mutual compliant roof systems.
F Deck
New Millennium steel roof deck type F (intermediate rib – IR) is approved for use as a component of Factory Mutual compliant roof systems.
B Deck
New Millennium steel roof deck type B (wide rib – WR) is approved for use as a component of Factory Mutual compliant roof systems.
N Deck
New Millennium steel roof deck type N (deep rib – DR) is approved for use as a component of Factory Mutual compliant roof systems.
N-Dek Cellular
New Millennium steel roof deck type NDC (N Cellular) is approved for use as a component of Factory Mutual compliant roof systems.
N-Dek Cellular Acoustical
New Millennium steel roof deck type NDCA (N Cellular Acoustical) is approved for use as a component of Factory Mutual compliant roof systems.
UL CERTIFICATIONS
New Millennium deck products are approved for use in UL fire rated assemblies. Please visit UL/ULC Online Certifications Directory, UL/ULC File Numbers R20577 and R22282 (links provided below) for an up-to-date listing of UL/ULC Designs in which New Millennium deck products have been approved. UL design numbering system has been provided below for your use in navigating to the specific construction types required for your project.
NUMBERING SYSTEM FOR UL DESIGNS
Floors - Ceilings
D200-299: Concrete on steel deck w/exposed grid system
D300-399: Concrete on steel deck w/mineral or fiber board
D500-599: Concrete on steel deck w/gypsum board
D700-899: Concrete on steel deck w/spray-applied fire-resistive material
D900-999: Concrete on steel deck w/no protection
E700-899: Concrete on steel deck w/spray-applied fire-resistive material
E900-999: Concrete on steel deck w/no protection
G200-299: Concrete on steel deck & steel joists w/exposed grid system
G500-599: Concrete on steel deck & steel joists w/gypsum board
G700-899: Concrete on steel deck & steel joists w/spray-applied fire-resistive material
Type 3.5VLSC in Joint System Design No. HW-S-0127
L700-899: Wood on steel deck w/spray-applied fire-resistive material
N700-899: Concrete on steel deck & steel joists w/spray-applied fire-resistive material
Roof - Ceiling
P200-299: Steel deck w/exposed grid system
P400-499: Steel deck w/metal lath
P500-599: Steel deck w/gypsum board
P700-899: Steel deck w/spray-applied fire-resistive material
P900-999: Steel deck w/no protection
Floors - Ceilings
D900-999: Concrete on steel deck (as structural framing member) w/no protection
L500-599: Wood on steel deck (as structural framing member) w/gypsum board
Floors - Ceilings (Canada)
F700-799: Concrete on steel deck w/spray-applied fire-resistive material – cementitious
F800-899: Concrete on steel deck w/spray-applied fire-resistive material – sprayed fibre
F900-999: Concrete on steel deck w/no protection
- New Millennium products meet Factory Mutual, Underwriters Laboratory and Underwriters Laboratories of Canada requirements.
- The Indiana, Virginia, Florida, Tennessee, and Arkansas facilities are ICC-certified.
- Deck types F, B, N, NW32, and Versa-Dek 2.0 & 3.5 (select interlocking and acoustical variations) are FM-approved for use as components in Class 1-60, 1-75 and 1-90 wind uplift metal roof decking construction.
- Steel deck products are approved by UL and listed in the UL Fire Resistance Directory.
- All acoustical deck has been tested in accordance with ANSI ASTM C423 and E795 to determine the noise reduction coefficient rating.
- Welders are certified in accordance with AWS D1.1 and D1.3.
- The Indiana, Virginia and Nevada facilities meet CSA Standard W47.1 in Division 2 for open-web joist.
- The Florida facility has Miami-Dade County approval.
- The Arkansas and Florida facilities are certified in accordance with the Houston, Texas, Building Code, section 1704.2.2.
- The Nevada and Mexico facilities are certified in accordance with the requirements of LA City.
- The Nevada facility is certified in accordance with the requirements of Clark County.